How much attic insulation do I need?
Most US attics should reach R-49 to R-60, or R-30 to R-49 in the warmest areas. R-49 takes about 14 in of blown-in cellulose or about 20 in of blown-in fiberglass.
How to use the insulation calculator
- Measure the attic floor, which is usually the same as the house footprint.
- Choose the insulation type you plan to use.
- Estimate your existing R-value. Measure the depth of what is there and multiply by about 3 for fiberglass.
- Choose a target R-value for your climate and read the inches to add.
Inches of insulation for each R-value
Starting from no insulation. Use the calculator if you already have some.
| Target | Blown-in fiberglass | Blown-in cellulose | Fiberglass batts |
|---|---|---|---|
| R-30 | 12.0 in | 8.6 in | 9.4 in |
| R-38 | 15.2 in | 10.9 in | 11.9 in |
| R-49 | 19.6 in | 14.0 in | 15.3 in |
| R-60 | 24.0 in | 17.1 in | 18.8 in |
Calculated with the same formulas as the calculator above. Change any number in the calculator for your exact size.
How the insulation calculator works
| Insulation | About R per inch |
|---|---|
| Blown-in fiberglass | 2.5 |
| Blown-in cellulose | 3.5 |
| Fiberglass batts | 3.2 |
| Open-cell spray foam | 3.6 |
| Closed-cell spray foam | 6.5 |
Example: a 1,000 sq ft attic to R-49
The attic has old batts rated about R-11. Reaching R-49 means adding R-38.
With blown-in cellulose at R-3.5 per inch, add 10.9 inches (about 905 cubic feet). At $2.15 per sq ft installed, that is about $2,150.
Recommended attic R-values
The U.S. Department of Energy recommends roughly R-30 to R-49 for attics in the warmest southern climates and R-49 to R-60 in most other parts of the country. Colder climates benefit most from higher values.
- Seal air leaks around lights, pipes and the attic hatch before adding insulation.
- Keep insulation away from recessed lights that are not rated for contact, and from furnace flues.
- Do not block soffit vents. Use baffles so air can flow under the roof.
Frequently asked questions
How much attic insulation do I need?
Most US homes should have R-49 to R-60 in the attic, or R-30 to R-49 in the hottest southern areas. That is roughly 14 to 20 inches of blown-in insulation.
How many inches is R-49?
About 14 inches of blown-in cellulose or about 20 inches of blown-in fiberglass.
Can I add new insulation on top of old?
Yes, if the old insulation is dry and free of mold or pests. Blown-in insulation can go right over old batts.
Is blown-in or batt insulation better?
Blown-in fills gaps and odd spaces better and is faster for open attics. Batts are easy for DIY between evenly spaced joists.
How many inches is R-38?
About 10.9 in of blown-in cellulose, 15.2 in of blown-in fiberglass, or 11.9 in of fiberglass batts.
How many inches is R-60?
About 17.1 in of blown-in cellulose or 24 in of blown-in fiberglass.
Results are estimates for planning. Material sizes, coverage and prices vary by product and location, so confirm with your supplier or contractor before you buy. See how we calculate. Last reviewed October 2026.